Published March 2002 | Version v1
Journal article

Assessment of integrity of components in piping of 500 MWe PHWR: using R-6 method

Description

The primary heat transport system of 500 MWe Indian PHWR comprises of straight pipes, elbows and headers. A study was conducted to qualify piping system for leak before break. R-6 method was used to assess integrity of system for leakage size crack (LSC), the margins on crack initiation load and unstable crack growth loads. Option 2 (material specific failure assessment diagram), Category 3 (ductile tearing) analysis was used for straight pipes, elbows and header. In order to enhance the confidence in the analytical results, detailed sensitivity analysis was also performed. For sensitivity analysis, variation in material properties, LSC was considered. The effect of variation in temperature on material properties was also considered. Tensile and fracture properties used for base and weld material data were generated from pipe material obtained from 220 MWe Nuclear Power Plant, under construction

Additional details

Identifiers

PII
S0029549301004885;

Publishing Information

Journal Title
Nuclear Engineering and Design
Journal Volume
212
Journal Issue
1-3
Journal Page Range
p. 99-108
ISSN
0029-5493
CODEN
NEDEAU

Optional Information

Copyright
Copyright (c) 2002 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.