CANDU 600 reactor output optimization
- 1. Atomic Energy of Canada Ltd., Sheridan Park, ON (Canada). CANDU Operations
- 2. New Brunswick Electric Power Commission, Point Lepreau, NB (Canada). Point Lepreau Generating Station
Description
As part of a program to reduce capital cost and construction schedule, Atomic Energy of Canada Ltd. - CANDU Operations has identified design improvement to increase the output of a CANDU-600 unit by 17%. These improvements are based on proven technology thereby ensuring that the uprated plant will perform to the same high standards of reliability and safety as other CANDU designs. This report presents comparisons of the uprated design to other CANDU designs and shows that the choice of design alternatives is based on the design, manufacturing, commissioning and operating experience gained through other CANDU designs which are already operating or in the process of being constructed
Additional details
Publishing Information
- Imprint Title
- Proceedings of the Canadian Nuclear Society 8. annual conference
- Imprint Pagination
- 483 p.
- Journal Page Range
- p. 441-448.
- Report number
- INIS-mf--12909
Conference
- Title
- Canadian Nuclear Society 8. annual conference.
- Dates
- 16-17 Jun 1987.
- Place
- Saint John, NB (Canada).
INIS
- Country of Publication
- Canada
- Country of Input or Organization
- Canada
- INIS RN
- 22069627
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CANDU TYPE REACTORS; MODIFICATIONS; POWER GENERATION
- Descriptors DEC
- HEAVY WATER MODERATED REACTORS; POWER REACTORS; PRESSURE TUBE REACTORS; REACTORS; THERMAL REACTORS