As part of a program to reduce capital cost and construction schedule, Atomic Energy of Canada Ltd. - CANDU Operations has identified design improvement to increase the output of a CANDU-600 unit by 17%. These improvements are based on proven technology thereby ensuring that the uprated plant will perform to the same high standards of reliability and safety as other CANDU designs. This report presents comparisons of the uprated design to other CANDU designs and shows that the choice of design alternatives is based on the design, manufacturing, commissioning and operating experience gained through other CANDU designs which are already operating or in the process of being constructed

Part of:
Proceedings of the Canadian Nuclear Society 8. annual conference

Additional details

Publishing Information

Imprint Title
Proceedings of the Canadian Nuclear Society 8. annual conference
Imprint Pagination
483 p.
Journal Page Range
p. 441-448.
Report number
INIS-mf--12909

Conference

Title
Canadian Nuclear Society 8. annual conference.
Dates
16-17 Jun 1987.
Place
Saint John, NB (Canada).

INIS

Country of Publication
Canada
Country of Input or Organization
Canada
INIS RN
22069627
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CANDU TYPE REACTORS; MODIFICATIONS; POWER GENERATION
Descriptors DEC
HEAVY WATER MODERATED REACTORS; POWER REACTORS; PRESSURE TUBE REACTORS; REACTORS; THERMAL REACTORS