Published 1980 | Version v1
Book

Numerical simulation in unsteady-state running of the 45MW scale model SUPER-PHENIX steam generator

  • 1. Electricite de France, 75 - Paris
  • 2. Societe Creusot-Loire, 75 - Paris (France)
  • 3. Novatome Industries, 92 - Le Plessis-Robinson (France)

Description

A 45 MW mock-up of SUPER-PHENIX steam generator was tested on the high power sodium-heated steam generator test loop (the C.G.V.S.). Running of the tests and analysis of the results were performed by the various parties interested in the development and construction of such units in France, viz. C.E.A., CREUSOT-LOIRE, EDF and NOVATOME. Digital simulation of the mock-up dynamic behaviour in the course of a number of operational tests under wide amplitude transient conditions was performed with a non-linear program i.e. the SICLE code. After a brief description of the mock-up and of the tests, an introduction is made of the computing code, followed by comments on the comparison between test and computation results. This comparison shows that digital simulation of the steam generator operation under transient conditions is very satisfactory: the maximum difference between the reckoned and the measured temperatures is 100C. (author)

Additional details

Publishing Information

Publisher
British Nuclear Energy Society.
Imprint Place
London
ISBN
0 7277 0095 2
Imprint Title
Boiler dynamics and control in nuclear power stations 2
Imprint Pagination
430 p.
Journal Page Range
p. 87-94.