Published December 1, 2014
| Version v1
Journal article
Upgrade and performance of the VERITAS telescope array
Creators
Description
The VERITAS collaboration has been observing VHE (E>100GeV) gamma rays since 2007. It has recently completed major upgrades of the photomultiplier tubes and pattern trigger. More than a year after these implementations, these efforts have shown to improve the performance with better noise reduction, faster source detection and lowered energy threshold. Further benefits are also expected from these upgrades
Availability note (English)
Available from http://dx.doi.org/10.1016/j.nima.2014.04.075Additional details
Identifiers
- DOI
- 10.1016/j.nima.2014.04.075;
- PII
- S0168-9002(14)00488-4;
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 766
- Journal Page Range
- p. 61-64
- ISSN
- 0168-9002
- CODEN
- NIMAER
Conference
- Title
- 8. international workshop on ring imaging Cherenkov detectors
- Acronym
- RICH2013
- Dates
- 2-6 Dec 2013
- Place
- Shonan, Kanagawa (Japan)
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 46125291
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S79: ASTROPHYSICS, COSMOLOGY AND ASTRONOMY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CHERENKOV COUNTERS; CHERENKOV RADIATION; DETECTION; GAMMA RADIATION; NOISE; PATTERN RECOGNITION; PERFORMANCE; PHOTOMULTIPLIERS; TELESCOPES
- Descriptors DEC
- ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; MEASURING INSTRUMENTS; PHOTOTUBES; RADIATION DETECTORS; RADIATIONS
Optional Information
- Copyright