This paper examines the applicability of the Target Motion Sampling (TMS) temperature treatment method together with track-length estimators. Several track-length estimator based quantities are calculated in four test cases using a preliminary implementation of the method in OpenMC. The results are compared to an NJOY-based reference. The study reveals a statistically significant bias in the estimator results, but the errors were found to only affect limited energy regions, and their magnitude is relatively small as long as energy-integrated estimators are considered. (author)

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Part of:
Proceedings of the international conference on physics of reactors (PHYSOR2014)

Additional details

Identifiers

Publishing Information

Imprint Title
Proceedings of the international conference on physics of reactors (PHYSOR2014)
Imprint Pagination
5489 p.
Journal Page Range
11 p.
Report number
JAEA-Conf--2014-003

Conference

Title
International conference on physics of reactors
Acronym
PHYSOR2014
Dates
28 Sep - 3 Oct 2014
Place
Kyoto (Japan)

Optional Information

Notes
Available as CD-ROM Data in PDF format, Folder Name: PAPERS, Paper ID: a11_1106078.pdf; 16 refs., 2 figs., 1 tab.