Filters
Results 1 - 10 of 66
Results 1 - 10 of 66.
Search took: 0.019 seconds
Sort by: date | relevance |
Rodrigues, R.G.S.; Pela, C.A.; Roque, S.F. A.C.
Proceedings of the 1st Ibero-Latin American and Caribbean Congress on Medical Physics. Mexico 981998
Proceedings of the 1st Ibero-Latin American and Caribbean Congress on Medical Physics. Mexico 981998
AbstractAbstract
[en] This paper shows an artificial neural network with an adequately topology for tomographic image reconstruction. The associated error function is derived and the learning algorithm is make. The simulated results are presented and demonstrate the existence of a generalized solution for nets with linear activation function. (Author)
Original Title
Modelo conexionista para reconstrucao de imagens tomograficas
Primary Subject
Source
Gaona, E. (ed.) (Universidad Autonoma Metropolitana, Mexico D.F. (Mexico)); Huitron, B.G. (ed.) (Universidad Autonoma del Estado de Mexico, Toluca (Mexico)); Asociacion Latinoamericana de Fisica Medica (ALFIM) (Mexico); Sociedad Espanola de Fisica Medica (SEFM) (Spain); Secretaria de Salud de Mexico (Mexico); Instituto Nacional de Cancerologia (Mexico); Organismo Internacional de Energia Atomica (IAEA), Vienna (Austria); Organizacion Panamericana de la Salud (Mexico); Organizacion Internacional de Fisica Medica (Mexico); Universidad Autonoma Metropolitana (Mexico); Instituto Nacional de Investigaciones Nucleares (Mexico); Universidad Autonoma del Estado de Mexico (Mexico); Universidad Nacional Autonoma de Mexico (Mexico); Direccion de Riesgos Radiologicos (Mexico); Comision Nacional de Seguridad Nuclear y Salvaguardias (Mexico); Sociedad Mexicana de Radioterapeutas, A.C. (Mexico); Centro de Investigacion y Estudios Avanzados, IPN (Mexico); Centro Universitario contra el Cancer, UANL (Mexico); Asociacion Mexicana de Fisica Medica, A.C. (Mexico); Sociedad de Fisica Medica de Nuevo Leon, A.C. (Mexico); Sociedades Nacionales de Fisica Medica de Latinoamerica y el Caribe (Mexico). Funding organisation: Med-Tec (United States); Nucletron (Mexico); Grupo Venta Internacional, S.A. de C.V. (Leibinger) (Mexico); PTW Freiburg (Germany); Scanditronix Medical AB (Mexico); Kodak (United States); Electronica y Medicina, S.A. (Mexico); Siemens (Germany); Electronica 2000, S.A. de C.V. (Mexico); 283 p; ISBN 968-835-419-8;
; 1998; p. 99-102; 1. Ibero-Latin American and Caribbean Congress on Medical Physics; 1. Congreso Iberolatinoamericano y del Caribe de Fisica Medica; Mexico, D.F. (Mexico); 22-25 Nov 1998

Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
LanguageLanguage
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
Venencia, D.; Bustos, S.; Zunino, S.
Proceedings of the 1st Ibero-Latin American and Caribbean Congress on Medical Physics. Mexico 981998
Proceedings of the 1st Ibero-Latin American and Caribbean Congress on Medical Physics. Mexico 981998
AbstractAbstract
[en] The objective of this work has been to implement a Total body irradiation technique that fulfill the following conditions: simplicity, repeatability, fast and comfortable positioning for the patient, homogeneity of the dose between 10-15 %, short times of treatments and In vivo dosimetric verifications. (Author)
Original Title
Tecnica de irradiacion corporal total: aspectos fisicos
Primary Subject
Source
Gaona, E. (ed.) (Universidad Autonoma Metropolitana, Mexico D.F. (Mexico)); Huitron, B.G. (ed.) (Universidad Autonoma del Estado de Mexico, Toluca (Mexico)); Asociacion Latinoamericana de Fisica Medica (ALFIM) (Mexico); Sociedad Espanola de Fisica Medica (SEFM) (Spain); Secretaria de Salud de Mexico (Mexico); Instituto Nacional de Cancerologia (Mexico); Organismo Internacional de Energia Atomica (IAEA), Vienna (Austria); Organizacion Panamericana de la Salud (Mexico); Organizacion Internacional de Fisica Medica (Mexico); Universidad Autonoma Metropolitana (Mexico); Instituto Nacional de Investigaciones Nucleares (Mexico); Universidad Autonoma del Estado de Mexico (Mexico); Universidad Nacional Autonoma de Mexico (Mexico); Direccion de Riesgos Radiologicos (Mexico); Comision Nacional de Seguridad Nuclear y Salvaguardias (Mexico); Sociedad Mexicana de Radioterapeutas, A.C. (Mexico); Centro de Investigacion y Estudios Avanzados, IPN (Mexico); Centro Universitario contra el Cancer, UANL (Mexico); Asociacion Mexicana de Fisica Medica, A.C. (Mexico); Sociedad de Fisica Medica de Nuevo Leon, A.C. (Mexico); Sociedades Nacionales de Fisica Medica de Latinoamerica y el Caribe (Mexico). Funding organisation: Med-Tec (United States); Nucletron (Mexico); Grupo Venta Internacional, S.A. de C.V. (Leibinger) (Mexico); PTW Freiburg (Germany); Scanditronix Medical AB (Mexico); Kodak (United States); Electronica y Medicina, S.A. (Mexico); Siemens (Germany); Electronica 2000, S.A. de C.V. (Mexico); 283 p; ISBN 968-835-419-8;
; 1998; p. 179-182; 1. Ibero-Latin American and Caribbean Congress on Medical Physics; 1. Congreso Iberolatinoamericano y del Caribe de Fisica Medica; Mexico, D.F. (Mexico); 22-25 Nov 1998

Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
Cortes I, M.E.; Ramirez G, F.P.
Proceedings of the 1st Ibero-Latin American and Caribbean Congress on Medical Physics. Mexico 981998
Proceedings of the 1st Ibero-Latin American and Caribbean Congress on Medical Physics. Mexico 981998
AbstractAbstract
[en] In this work it is presented an application of the cause-effect diagram method or Ichikawa method identifying the elements that allow to diminish accidents when the radioactive materials are transported. It is considered the transport of hazardous materials which include radioactive materials in the period: December 1996 until March 1997. Among the identified elements by this method it is possible to mention: the road type, the radioactive source protection, the grade driver responsibility and the preparation that the OEP has in the radioactive material management. It is showed the differences found between the country inner roads and the Mexico City area. (Author)
Original Title
Elementos para disminuir accidentes radiactivos
Primary Subject
Source
Gaona, E. (ed.) (Universidad Autonoma Metropolitana, Mexico D.F. (Mexico)); Huitron, B.G. (ed.) (Universidad Autonoma del Estado de Mexico, Toluca (Mexico)); Asociacion Latinoamericana de Fisica Medica (ALFIM) (Mexico); Sociedad Espanola de Fisica Medica (SEFM) (Spain); Secretaria de Salud de Mexico (Mexico); Instituto Nacional de Cancerologia (Mexico); Organismo Internacional de Energia Atomica (IAEA), Vienna (Austria); Organizacion Panamericana de la Salud (Mexico); Organizacion Internacional de Fisica Medica (Mexico); Universidad Autonoma Metropolitana (Mexico); Instituto Nacional de Investigaciones Nucleares (Mexico); Universidad Autonoma del Estado de Mexico (Mexico); Universidad Nacional Autonoma de Mexico (Mexico); Direccion de Riesgos Radiologicos (Mexico); Comision Nacional de Seguridad Nuclear y Salvaguardias (Mexico); Sociedad Mexicana de Radioterapeutas, A.C. (Mexico); Centro de Investigacion y Estudios Avanzados, IPN (Mexico); Centro Universitario contra el Cancer, UANL (Mexico); Asociacion Mexicana de Fisica Medica, A.C. (Mexico); Sociedad de Fisica Medica de Nuevo Leon, A.C. (Mexico); Sociedades Nacionales de Fisica Medica de Latinoamerica y el Caribe (Mexico). Funding organisation: Med-Tec (United States); Nucletron (Mexico); Grupo Venta Internacional, S.A. de C.V. (Leibinger) (Mexico); PTW Freiburg (Germany); Scanditronix Medical AB (Mexico); Kodak (United States); Electronica y Medicina, S.A. (Mexico); Siemens (Germany); Electronica 2000, S.A. de C.V. (Mexico); 283 p; ISBN 968-835-419-8;
; 1998; p. 75-77; 1. Ibero-Latin American and Caribbean Congress on Medical Physics; 1. Congreso Iberolatinoamericano y del Caribe de Fisica Medica; Mexico, D.F. (Mexico); 22-25 Nov 1998

Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
Lescano, R.; Caspani, C.
Proceedings of the 1st Ibero-Latin American and Caribbean Congress on Medical Physics. Mexico 981998
Proceedings of the 1st Ibero-Latin American and Caribbean Congress on Medical Physics. Mexico 981998
AbstractAbstract
[en] In this work it is proposed a quality indicator for actions of radiological protection considering all personal doses to occupational exposed personnel (OEP) they expressed as a middle taking into account to the work loading at each installation. (Author)
Original Title
Un indicador para objetivar las mejoras logradas en Proteccion radiologica aplicado a evaluar el accionar de radiofisica sanitaria de Santa Fe - Argentina
Primary Subject
Source
Gaona, E. (ed.) (Universidad Autonoma Metropolitana, Mexico D.F. (Mexico)); Huitron, B.G. (ed.) (Universidad Autonoma del Estado de Mexico, Toluca (Mexico)); Asociacion Latinoamericana de Fisica Medica (ALFIM) (Mexico); Sociedad Espanola de Fisica Medica (SEFM) (Spain); Secretaria de Salud de Mexico (Mexico); Instituto Nacional de Cancerologia (Mexico); Organismo Internacional de Energia Atomica (IAEA), Vienna (Austria); Organizacion Panamericana de la Salud (Mexico); Organizacion Internacional de Fisica Medica (Mexico); Universidad Autonoma Metropolitana (Mexico); Instituto Nacional de Investigaciones Nucleares (Mexico); Universidad Autonoma del Estado de Mexico (Mexico); Universidad Nacional Autonoma de Mexico (Mexico); Direccion de Riesgos Radiologicos (Mexico); Comision Nacional de Seguridad Nuclear y Salvaguardias (Mexico); Sociedad Mexicana de Radioterapeutas, A.C. (Mexico); Centro de Investigacion y Estudios Avanzados, IPN (Mexico); Centro Universitario contra el Cancer, UANL (Mexico); Asociacion Mexicana de Fisica Medica, A.C. (Mexico); Sociedad de Fisica Medica de Nuevo Leon, A.C. (Mexico); Sociedades Nacionales de Fisica Medica de Latinoamerica y el Caribe (Mexico). Funding organisation: Med-Tec (United States); Nucletron (Mexico); Grupo Venta Internacional, S.A. de C.V. (Leibinger) (Mexico); PTW Freiburg (Germany); Scanditronix Medical AB (Mexico); Kodak (United States); Electronica y Medicina, S.A. (Mexico); Siemens (Germany); Electronica 2000, S.A. de C.V. (Mexico); 283 p; ISBN 968-835-419-8;
; 1998; p. 88-90; 1. Ibero-Latin American and Caribbean Congress on Medical Physics; 1. Congreso Iberolatinoamericano y del Caribe de Fisica Medica; Mexico, D.F. (Mexico); 22-25 Nov 1998

Record Type
Miscellaneous
Literature Type
Conference; Numerical Data
Report Number
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
Briquet, C.; Coutinho, C.M.C.; Mota, H.C.; Tavares, E.
Proceedings of the 1st Ibero-Latin American and Caribbean Congress on Medical Physics. Mexico 981998
Proceedings of the 1st Ibero-Latin American and Caribbean Congress on Medical Physics. Mexico 981998
AbstractAbstract
[en] This paper presents the preliminary results and the methodology followed by the implementation of a Quality Assurance Program in public hospitals at Rio de Janeiro. We observed that the main problems of image are due to the processing. None facility has a dedicated processor and the processor daily quality control is a concern not yet adopted. (Author)
Primary Subject
Secondary Subject
Source
Gaona, E. (ed.) (Universidad Autonoma Metropolitana, Mexico D.F. (Mexico)); Huitron, B.G. (ed.) (Universidad Autonoma del Estado de Mexico, Toluca (Mexico)); Asociacion Latinoamericana de Fisica Medica (ALFIM) (Mexico); Sociedad Espanola de Fisica Medica (SEFM) (Spain); Secretaria de Salud de Mexico (Mexico); Instituto Nacional de Cancerologia (Mexico); Organismo Internacional de Energia Atomica (IAEA), Vienna (Austria); Organizacion Panamericana de la Salud (Mexico); Organizacion Internacional de Fisica Medica (Mexico); Universidad Autonoma Metropolitana (Mexico); Instituto Nacional de Investigaciones Nucleares (Mexico); Universidad Autonoma del Estado de Mexico (Mexico); Universidad Nacional Autonoma de Mexico (Mexico); Direccion de Riesgos Radiologicos (Mexico); Comision Nacional de Seguridad Nuclear y Salvaguardias (Mexico); Sociedad Mexicana de Radioterapeutas, A.C. (Mexico); Centro de Investigacion y Estudios Avanzados, IPN (Mexico); Centro Universitario contra el Cancer, UANL (Mexico); Asociacion Mexicana de Fisica Medica, A.C. (Mexico); Sociedad de Fisica Medica de Nuevo Leon, A.C. (Mexico); Sociedades Nacionales de Fisica Medica de Latinoamerica y el Caribe (Mexico). Funding organisation: Med-Tec (United States); Nucletron (Mexico); Grupo Venta Internacional, S.A. de C.V. (Leibinger) (Mexico); PTW Freiburg (Germany); Scanditronix Medical AB (Mexico); Kodak (United States); Electronica y Medicina, S.A. (Mexico); Siemens (Germany); Electronica 2000, S.A. de C.V. (Mexico); 283 p; ISBN 968-835-419-8;
; 1998; p. 96-98; 1. Ibero-Latin American and Caribbean Congress on Medical Physics; 1. Congreso Iberolatinoamericano y del Caribe de Fisica Medica; Mexico, D.F. (Mexico); 22-25 Nov 1998

Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] The objective of this work is to propose a new model based in the Fermi-Dirac distribution, in which it is considered that the photon beams possess a particles behavior when they interact with the matter. (Author)
Original Title
Un modelo basado en la distribucion de Fermi-Dirac para determinar el perfil de dosis de un haz de fotones
Primary Subject
Source
Gaona, E. (ed.) (Universidad Autonoma Metropolitana, Mexico D.F. (Mexico)); Huitron, B.G. (ed.) (Universidad Autonoma del Estado de Mexico, Toluca (Mexico)); Asociacion Latinoamericana de Fisica Medica (ALFIM) (Mexico); Sociedad Espanola de Fisica Medica (SEFM) (Spain); Secretaria de Salud de Mexico (Mexico); Instituto Nacional de Cancerologia (Mexico); Organismo Internacional de Energia Atomica (IAEA), Vienna (Austria); Organizacion Panamericana de la Salud (Mexico); Organizacion Internacional de Fisica Medica (Mexico); Universidad Autonoma Metropolitana (Mexico); Instituto Nacional de Investigaciones Nucleares (Mexico); Universidad Autonoma del Estado de Mexico (Mexico); Universidad Nacional Autonoma de Mexico (Mexico); Direccion de Riesgos Radiologicos (Mexico); Comision Nacional de Seguridad Nuclear y Salvaguardias (Mexico); Sociedad Mexicana de Radioterapeutas, A.C. (Mexico); Centro de Investigacion y Estudios Avanzados, IPN (Mexico); Centro Universitario contra el Cancer, UANL (Mexico); Asociacion Mexicana de Fisica Medica, A.C. (Mexico); Sociedad de Fisica Medica de Nuevo Leon, A.C. (Mexico); Sociedades Nacionales de Fisica Medica de Latinoamerica y el Caribe (Mexico). Funding organisation: Med-Tec (United States); Nucletron (Mexico); Grupo Venta Internacional, S.A. de C.V. (Leibinger) (Mexico); PTW Freiburg (Germany); Scanditronix Medical AB (Mexico); Kodak (United States); Electronica y Medicina, S.A. (Mexico); Siemens (Germany); Electronica 2000, S.A. de C.V. (Mexico); 283 p; ISBN 968-835-419-8;
; 1998; p. 277-278; 1. Ibero-Latin American and Caribbean Congress on Medical Physics; 1. Congreso Iberolatinoamericano y del Caribe de Fisica Medica; Mexico, D.F. (Mexico); 22-25 Nov 1998

Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
Lima, M.A.F.; Borges, J.C.; Mota, H.C.
Proceedings of the 1st Ibero-Latin American and Caribbean Congress on Medical Physics. Mexico 981998
Proceedings of the 1st Ibero-Latin American and Caribbean Congress on Medical Physics. Mexico 981998
AbstractAbstract
[en] In order to put into practice radiological protection has been required conversion factors for environmental dose equivalent determination to air kerma value for different kinds of photon and electron beams, such dose values have been determined in a spheric phantom of 30 cm diameter in a alignment field and expanded in a depth of this sphere. Details will be given for determining of equivalent dose distribution calculation using Monte Carlo computational method (ESG4) following the recommendations of ICRU. (Author)
Original Title
Determinacao do equivalente de dose ambiental, H*(d), em uma instalacao de radioterapia
Primary Subject
Source
Gaona, E. (ed.) (Universidad Autonoma Metropolitana, Mexico D.F. (Mexico)); Huitron, B.G. (ed.) (Universidad Autonoma del Estado de Mexico, Toluca (Mexico)); Asociacion Latinoamericana de Fisica Medica (ALFIM) (Mexico); Sociedad Espanola de Fisica Medica (SEFM) (Spain); Secretaria de Salud de Mexico (Mexico); Instituto Nacional de Cancerologia (Mexico); Organismo Internacional de Energia Atomica (IAEA), Vienna (Austria); Organizacion Panamericana de la Salud (Mexico); Organizacion Internacional de Fisica Medica (Mexico); Universidad Autonoma Metropolitana (Mexico); Instituto Nacional de Investigaciones Nucleares (Mexico); Universidad Autonoma del Estado de Mexico (Mexico); Universidad Nacional Autonoma de Mexico (Mexico); Direccion de Riesgos Radiologicos (Mexico); Comision Nacional de Seguridad Nuclear y Salvaguardias (Mexico); Sociedad Mexicana de Radioterapeutas, A.C. (Mexico); Centro de Investigacion y Estudios Avanzados, IPN (Mexico); Centro Universitario contra el Cancer, UANL (Mexico); Asociacion Mexicana de Fisica Medica, A.C. (Mexico); Sociedad de Fisica Medica de Nuevo Leon, A.C. (Mexico); Sociedades Nacionales de Fisica Medica de Latinoamerica y el Caribe (Mexico). Funding organisation: Med-Tec (United States); Nucletron (Mexico); Grupo Venta Internacional, S.A. de C.V. (Leibinger) (Mexico); PTW Freiburg (Germany); Scanditronix Medical AB (Mexico); Kodak (United States); Electronica y Medicina, S.A. (Mexico); Siemens (Germany); Electronica 2000, S.A. de C.V. (Mexico); 283 p; ISBN 968-835-419-8;
; 1998; p. 64-66; 1. Ibero-Latin American and Caribbean Congress on Medical Physics; 1. Congreso Iberolatinoamericano y del Caribe de Fisica Medica; Mexico, D.F. (Mexico); 22-25 Nov 1998

Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
LanguageLanguage
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
Paredes G, L.; Genis S, R.
Proceedings of the 1st Ibero-Latin American and Caribbean Congress on Medical Physics. Mexico 981998
Proceedings of the 1st Ibero-Latin American and Caribbean Congress on Medical Physics. Mexico 981998
AbstractAbstract
[en] It is analyzed the use of a perspex solid phantom, adequately referred to a water phantom, as an auxiliary alternative for the daily stability verification routines or constance of radiation beam, as an option in the case of radiotherapy installations with high charge of accelerator working and with basic dosimetry equipment. (Author)
Original Title
El Perspex en las rutinas de verificacion del haz en un acelerador
Primary Subject
Secondary Subject
Source
Gaona, E. (ed.) (Universidad Autonoma Metropolitana, Mexico D.F. (Mexico)); Huitron, B.G. (ed.) (Universidad Autonoma del Estado de Mexico, Toluca (Mexico)); Asociacion Latinoamericana de Fisica Medica (ALFIM) (Mexico); Sociedad Espanola de Fisica Medica (SEFM) (Spain); Secretaria de Salud de Mexico (Mexico); Instituto Nacional de Cancerologia (Mexico); Organismo Internacional de Energia Atomica (IAEA), Vienna (Austria); Organizacion Panamericana de la Salud (Mexico); Organizacion Internacional de Fisica Medica (Mexico); Universidad Autonoma Metropolitana (Mexico); Instituto Nacional de Investigaciones Nucleares (Mexico); Universidad Autonoma del Estado de Mexico (Mexico); Universidad Nacional Autonoma de Mexico (Mexico); Direccion de Riesgos Radiologicos (Mexico); Comision Nacional de Seguridad Nuclear y Salvaguardias (Mexico); Sociedad Mexicana de Radioterapeutas, A.C. (Mexico); Centro de Investigacion y Estudios Avanzados, IPN (Mexico); Centro Universitario contra el Cancer, UANL (Mexico); Asociacion Mexicana de Fisica Medica, A.C. (Mexico); Sociedad de Fisica Medica de Nuevo Leon, A.C. (Mexico); Sociedades Nacionales de Fisica Medica de Latinoamerica y el Caribe (Mexico). Funding organisation: Med-Tec (United States); Nucletron (Mexico); Grupo Venta Internacional, S.A. de C.V. (Leibinger) (Mexico); PTW Freiburg (Germany); Scanditronix Medical AB (Mexico); Kodak (United States); Electronica y Medicina, S.A. (Mexico); Siemens (Germany); Electronica 2000, S.A. de C.V. (Mexico); 283 p; ISBN 968-835-419-8;
; 1998; p. 244-246; 1. Ibero-Latin American and Caribbean Congress on Medical Physics; 1. Congreso Iberolatinoamericano y del Caribe de Fisica Medica; Mexico, D.F. (Mexico); 22-25 Nov 1998

Record Type
Miscellaneous
Literature Type
Conference; Numerical Data
Report Number
Country of publication
ACCELERATORS, BEAMS, DATA, ENERGY RANGE, ESTERS, INFORMATION, INTERNATIONAL ORGANIZATIONS, MATERIALS, MEASURING INSTRUMENTS, MOCKUP, NUMERICAL DATA, ORGANIC COMPOUNDS, ORGANIC POLYMERS, PETROCHEMICALS, PETROLEUM PRODUCTS, PLASTICS, POLYACRYLATES, POLYMERS, POLYVINYLS, RADIATION DETECTORS, STRUCTURAL MODELS, SYNTHETIC MATERIALS
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
Amalia P, R.; Piotrkowski, G.; Mura, E.S. La
Proceedings of the 1st Ibero-Latin American and Caribbean Congress on Medical Physics. Mexico 981998
Proceedings of the 1st Ibero-Latin American and Caribbean Congress on Medical Physics. Mexico 981998
AbstractAbstract
[en] In this work is proposed the application of the Onditas transformation to evaluate the characteristics of frequency levels of the image of a transversal cutting of an activity homogeneous distribution source. The objective is to confirm if it is possible to separate the distinct factors that determine the characteristics of this image: lack of correctness by attenuation, rings presence and statistic noise, in the different levels of frequency resolution. (Author)
Original Title
Analisis de la uniformidad tomografica en estudios de SPECT con el metodode Onditas
Primary Subject
Source
Gaona, E. (ed.) (Universidad Autonoma Metropolitana, Mexico D.F. (Mexico)); Huitron, B.G. (ed.) (Universidad Autonoma del Estado de Mexico, Toluca (Mexico)); Asociacion Latinoamericana de Fisica Medica (ALFIM) (Mexico); Sociedad Espanola de Fisica Medica (SEFM) (Spain); Secretaria de Salud de Mexico (Mexico); Instituto Nacional de Cancerologia (Mexico); Organismo Internacional de Energia Atomica (IAEA), Vienna (Austria); Organizacion Panamericana de la Salud (Mexico); Organizacion Internacional de Fisica Medica (Mexico); Universidad Autonoma Metropolitana (Mexico); Instituto Nacional de Investigaciones Nucleares (Mexico); Universidad Autonoma del Estado de Mexico (Mexico); Universidad Nacional Autonoma de Mexico (Mexico); Direccion de Riesgos Radiologicos (Mexico); Comision Nacional de Seguridad Nuclear y Salvaguardias (Mexico); Sociedad Mexicana de Radioterapeutas, A.C. (Mexico); Centro de Investigacion y Estudios Avanzados, IPN (Mexico); Centro Universitario contra el Cancer, UANL (Mexico); Asociacion Mexicana de Fisica Medica, A.C. (Mexico); Sociedad de Fisica Medica de Nuevo Leon, A.C. (Mexico); Sociedades Nacionales de Fisica Medica de Latinoamerica y el Caribe (Mexico). Funding organisation: Med-Tec (United States); Nucletron (Mexico); Grupo Venta Internacional, S.A. de C.V. (Leibinger) (Mexico); PTW Freiburg (Germany); Scanditronix Medical AB (Mexico); Kodak (United States); Electronica y Medicina, S.A. (Mexico); Siemens (Germany); Electronica 2000, S.A. de C.V. (Mexico); 283 p; ISBN 968-835-419-8;
; 1998; p. 31-34; 1. Ibero-Latin American and Caribbean Congress on Medical Physics; 1. Congreso Iberolatinoamericano y del Caribe de Fisica Medica; Mexico, D.F. (Mexico); 22-25 Nov 1998

Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
BETA DECAY RADIOISOTOPES, BETA-MINUS DECAY RADIOISOTOPES, COMPUTERIZED TOMOGRAPHY, EMISSION COMPUTED TOMOGRAPHY, HOURS LIVING RADIOISOTOPES, INTERMEDIATE MASS NUCLEI, INTERNAL CONVERSION RADIOISOTOPES, ISOMERIC TRANSITION ISOTOPES, ISOTOPES, MEDICINE, NUCLEI, ODD-EVEN NUCLEI, RADIOISOTOPES, TECHNETIUM ISOTOPES, TOMOGRAPHY, YEARS LIVING RADIOISOTOPES
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
Becker, P.H.B.; Peres, M.A.L.; Moreira, A.J.C.; Nette, H.P.
Proceedings of the 1st Ibero-Latin American and Caribbean Congress on Medical Physics. Mexico 981998
Proceedings of the 1st Ibero-Latin American and Caribbean Congress on Medical Physics. Mexico 981998
AbstractAbstract
[en] Manufacturers of ionization chamber dosimeters for radiotherapy maintain only sales representatives in Brazil with no servicing capability causing difficulties to customers/users to get broken equipment back into operation. Aiming to partially solve this problem, a laboratory for maintenance, repair and electrical calibration was started in 1995 with the support of a two year IAEA Technical Assistance Project (BRA/1/031). (Author)
Original Title
Implementacao de um laboratorio para manutencao, reparo e calibracao eletrica de dosimetros baseados em camaras de ionizacao, utilizados em radioterapia
Source
Gaona, E. (ed.) (Universidad Autonoma Metropolitana, Mexico D.F. (Mexico)); Huitron, B.G. (ed.) (Universidad Autonoma del Estado de Mexico, Toluca (Mexico)); Asociacion Latinoamericana de Fisica Medica (ALFIM) (Mexico); Sociedad Espanola de Fisica Medica (SEFM) (Spain); Secretaria de Salud de Mexico (Mexico); Instituto Nacional de Cancerologia (Mexico); Organismo Internacional de Energia Atomica (IAEA), Vienna (Austria); Organizacion Panamericana de la Salud (Mexico); Organizacion Internacional de Fisica Medica (Mexico); Universidad Autonoma Metropolitana (Mexico); Instituto Nacional de Investigaciones Nucleares (Mexico); Universidad Autonoma del Estado de Mexico (Mexico); Universidad Nacional Autonoma de Mexico (Mexico); Direccion de Riesgos Radiologicos (Mexico); Comision Nacional de Seguridad Nuclear y Salvaguardias (Mexico); Sociedad Mexicana de Radioterapeutas, A.C. (Mexico); Centro de Investigacion y Estudios Avanzados, IPN (Mexico); Centro Universitario contra el Cancer, UANL (Mexico); Asociacion Mexicana de Fisica Medica, A.C. (Mexico); Sociedad de Fisica Medica de Nuevo Leon, A.C. (Mexico); Sociedades Nacionales de Fisica Medica de Latinoamerica y el Caribe (Mexico). Funding organisation: Med-Tec (United States); Nucletron (Mexico); Grupo Venta Internacional, S.A. de C.V. (Leibinger) (Mexico); PTW Freiburg (Germany); Scanditronix Medical AB (Mexico); Kodak (United States); Electronica y Medicina, S.A. (Mexico); Siemens (Germany); Electronica 2000, S.A. de C.V. (Mexico); 283 p; ISBN 968-835-419-8;
; 1998; p. 153-157; 1. Ibero-Latin American and Caribbean Congress on Medical Physics; 1. Congreso Iberolatinoamericano y del Caribe de Fisica Medica; Mexico, D.F. (Mexico); 22-25 Nov 1998

Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
LanguageLanguage
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
1 | 2 | 3 | Next |