Filters
Results 1 - 10 of 3625
Results 1 - 10 of 3625.
Search took: 0.029 seconds
Sort by: date | relevance |
AbstractAbstract
No abstract available
Original Title
HF-Gradientenflipper zur kohaerenten Energieverschiebung von Neutronen
Source
Oesterreichische Physikalische Gesellschaft, Vienna; 97 p; Sep 1987; p. 49; 1987 Annual convention of the Austrian Physical Society; Vienna (Austria); 21-25 Sep 1987; Published in summary form only.
Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
No abstract available
Source
Pintschovius, L. (ed.); Kernforschungszentrum Karlsruhe (F.R. Germany). Inst. fuer Angewandte Kernphysik; p. 107; Nov 1975; Short communication only.
Record Type
Report
Literature Type
Progress Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
No abstract available
Original Title
Fermi-Chopper fuer hohe Drehzahlen
Source
Pintschovius, L. (ed.); Kernforschungszentrum Karlsruhe (F.R. Germany). Inst. fuer Angewandte Kernphysik; p. 104-106; Nov 1975; 1 fig.; 1 tab. Short communication only.
Record Type
Report
Literature Type
Progress Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Tsvang, L.; Shani, G.
The second regional mediterranean congress on radiation protection; 20th Regional Congress of the Israel Radiation Protection Association. Program and extended abstracts1997
The second regional mediterranean congress on radiation protection; 20th Regional Congress of the Israel Radiation Protection Association. Program and extended abstracts1997
AbstractAbstract
[en] Neutron energy spectrum measurement in the energy range 50 keV to a few MeV is very important for scientific and medical applications. Neutron dosimetry is very important as well but difficult to achieve. Several methods are generally used for these purposes. None of the methods is adequate in the low energy range. In the present work, a new neutron spectrometer is described. The spectrometer is based on using a BF 3-detector for measuring thermal neutrons and polyethylene moderator of various thicknesses for neutron thermalization. A response matrix was calculated with the MCNP code for a certain distance between neutron source and BF 3-detector. Bach value in the response matrix was obtained as an integral of the product of the neutron spectrum, after thermalization for a given moderator thickness due to a certain neutron source energy at the detector, and the energy response of the detector. The number of thermal neutrons was measured for twenty polyethylene moderator thicknesses with and without Cd-foil between neutron source and moderator. The system was tested with an Am-Be neutron source. The 20 x 20 response matrix allows a neutron spectrum determination in the 0- 10 MeV energy range, with 0.5 MeV steps. Different ways of matrix formation are described and results are presented. A comparison of the present results with those obtained with a liquid scintillator and unfolding method is shown. The neutron dose is obtained from the neutron spectrum . (authors)
Source
Israel Radiation Protection Association (Israel); 321 p; 16 Nov 1997; p. 185; 2. regional mediterranean congress on radiation protection; Tel-Aviv (Israel); 16-20 Nov 1997; 20. regional congress of the Israel Radiation Protection Association; Tel-Aviv (Israel); 16-20 Nov 1997
Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
No abstract available
Original Title
Neutronenkleinwinkelstreuung an Metall-Wasserstoff-Systemen
Source
Oesterreichische Physikalische Gesellschaft, Vienna; 97 p; Sep 1987; p. 48; 1987 Annual convention of the Austrian Physical Society; Vienna (Austria); 21-25 Sep 1987; Published in summary form only.
Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
Bilkenrot, R.; Rodik, H.; Schwenkner, V.; Mikhaehlis, B.
XI International symposium on nuclear electronics1983
XI International symposium on nuclear electronics1983
AbstractAbstract
No abstract available
Original Title
Universal'nyj upravlyayushchij modul' privodov na baze mikro-EhVM i ego primenenie v spektrometre SPN-1
Source
Komenskeho Univ., Bratislava (Czechoslovakia); 114 p; 1983; p. X/6; 11. international symposium on nuclear electronics; Bratislava (Czechoslovakia); 6-12 Sep 1983; Published in summary form only.
Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
Majdob, M.M.; Shihub, S.I.
Seminar on the use of research reactors in fundamental and applied sciences. Programme and abstracts1984
Seminar on the use of research reactors in fundamental and applied sciences. Programme and abstracts1984
AbstractAbstract
[en] Short communication
Secondary Subject
Source
Tajoura Nuclear Research Centre, Tripoli (Libya); 82 p; 1984; p. 16; Seminar on the use of research reactors in fundamental and applied sciences; Tajoura (Libyan Arab Jamahiriya); 16-20 Sep 1984; Also available from Tajoura Nuclear Research Centre, Tajoura/Tripoli, Libya
Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] A prototype Parallel Plate Neutron spectrometer based on neutron moderation was built in 1975 at EGN Petten in order to investigate leakage neutron spectra at (shielded) nn-sources and nn-beams in laboratory areas. The PPN-spectrometer consists of 27 polythene plates (22 x 22 x 1 cm3) which are vertically inserted into a near cubical box also made of polythene. The box is lined at the inner side with a 1 cm thick layer of boron-plastic material except at the front side (source side). The total dimension of the PPN-spectrometer is 30 x 30 x 26 cm3. A small BF-counter fits into a vertical slit of one of the polythene moderator plates (the detector plate) which can be inserted at any position between the other vertical plates. Some experiments with the spectrometer are described
Source
Battelle Pacific Northwest Labs., Richland, WA (USA); p. 17-24; 1978; p. 17-24; 7. DOE workshop on personnel neutron dosimetry; London, UK; 23 - 25 Oct 1978
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Baluka, G.; Vajdkhaze, F.; Elizarov, O.I.; Ermakov, V.A.; Zaleski, T.; Ishmukhametov, M.Z.; Natkanets, I.; Chivkin, V.I.
XI International symposium on nuclear electronics1983
XI International symposium on nuclear electronics1983
AbstractAbstract
No abstract available
Original Title
Distantsionnoe upravlenie s raspredelennym intellektom dlya mnogodetektornogo nejtronnogo spektrometra KDSOG-2
Source
Komenskeho Univ., Bratislava (Czechoslovakia); 114 p; 1983; p. XI/83; 11. international symposium on nuclear electronics; Bratislava (Czechoslovakia); 6-12 Sep 1983; Published in summary form only.
Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
No abstract available
Original Title
Peredvizhnoj monokhromator nejtronnogo spektrometra
Source
For English translation see the journal Instrum. Exp. Tech.
Record Type
Journal Article
Journal
Pribory i Tekhnika Ehksperimenta; (no.4); p. 56-57
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
1 | 2 | 3 | Next |