Jolley, L. Jr.; Zippler, D.B.; Cofer, C.H.; Harper, J.A.
Du Pont de Nemours (E.I.) and Co., Aiken, SC (USA). Savannah River Plant1978
Du Pont de Nemours (E.I.) and Co., Aiken, SC (USA). Savannah River Plant1978
AbstractAbstract
[en] Two piece supplied-air plastic suits are used extensively at the Savannah River Plant for personnel protection against inhalation of airborne plutonium and tritium. Worker comfort and noise level problems gave impetus to development of an improved suit and aid distribution system. The resulting plastic suit and development work are discussed. The plastic suit unit cost is less than $20, the hearing zone noise level is less than 75 dBA, protection factors exceed 10,000, and user comfort is approved. This suit is expected to meet performance requirements for unrestricted use
Original Title
For personnel protection against inhalation of airborne plutonium and tritium
Primary Subject
Secondary Subject
Source
Jun 1978; 15 p; 23. meeting of the Health Physics Society; Minneapolis, MN, USA; 18 - 23 Jun 1978; CONF-780657--3; Available from NTIS., PC A02/MF A01
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
ACTINIDES, BETA DECAY RADIOISOTOPES, BETA-MINUS DECAY RADIOISOTOPES, CLOTHING, ELEMENTS, HYDROGEN ISOTOPES, INTAKE, ISOTOPES, LIGHT NUCLEI, METALS, NATIONAL ORGANIZATIONS, NUCLEI, ODD-EVEN NUCLEI, ORGANIC COMPOUNDS, POLYMERS, RADIOISOTOPES, TESTING, TRANSURANIUM ELEMENTS, US AEC, US ERDA, US ORGANIZATIONS, YEARS LIVING RADIOISOTOPES