[en] This topical report presents representative verification and qualification of the selected Westinghouse structural analysis computer codes. The selected codes include WESTDYN7, FIXFM3, WESDYN2, STRUDL, THESSE, WECAN, SAND, SPECTA, MODAL, DARI-WOSTAS and STHRUST which are utilized in dynamic and static analyses to determine forces, stresses and deformations of components. The verification and qualification follow the established Westinghouse procedures and instructions which are in compliance with the AEC and the ASME regulations for design control and documentation. Capability and description of each code are provided to give information on the basic features and methods adopted
Primary Subject
Source
May 1977; 257 p; Westinghouse Electric Corp., Pittsburgh, PA