McGuire, J.C.; Brehm, W.F.
Hanford Engineering Development Lab., Richland, WA (USA)1978
Hanford Engineering Development Lab., Richland, WA (USA)1978
AbstractAbstract
[en] At liquid metal cooled reactor operating temperatures, radioactive corrosion product transport and deposition in the primary system will be sufficiently high to limit access time for maintenance of system components. A radionuclide trap has been developed to aid in controlling radioactivity transport. This is a device which is located above the reactor core and which acts as a getter, physically immobilizing radioactive corrosion products, particularly 54Mn. Nickel is the getter material used. It is most effective at temperatures above 4500C and effectiveness increases with increasing temperature. Prototype traps have been tested in sodium loops for 40,000 hours at reactor primary temperatures and sodium velocities. Several possible in-reactor trap sites were considered but a location within the top of each driver assembly was chosen as the most convenient and effective. In this position the trap is changed each time fuel is changed
Primary Subject
Source
Oct 1978; 25 p; 1978 winter meeting of American Nuclear Society; Washington, DC, USA; 12 - 17 Nov 1978; CONF-781105--80; Available from NTIS., PC A02/MF A01