AbstractAbstract
[en] A computational procedure for calculating the C-V characteristic, the plasma arc-drop and other important parameters for a cesium vapor thermionic energy converter has been developed. The original theory dealing with the constant electron temperature has been extended to treat the problem for the variable electron temperature. Comparison between the two cases shows that the C-V characteristic moves generally toward the left as the electron thermal conductivity decreases, but the magnitude of ths degradation appears small
Primary Subject
Source
Sep 1978; 98 p; Available from NTIS., PC A05/MF A01