[en] The thermal design for a stereographic viewing system is presented. The design incorporates an annular heat pipe and thermal isolation techniques. Test results are compared with design predictions for a prototype configuration. Test data obtained during heat pipe startup showing temperature gradients along the evaporator wall are presented. Correlations relating maximum wall temperature differences to a liquid Reynolds number were obtained at low power levels. These results are compared with Nusselt's Falling Film theory
Primary Subject
Secondary Subject
Source
1979; 20 p; AIAA terrestrial energy systems conference; Orlando, FL, USA; 4 - 6 Jun 1979; CONF-790611--1; Available from NTIS., PC A02/MF A01