AbstractAbstract
[en] A secondary emission chamber (SEC) has been built using .00025'' aluminum foils with a 200A vacuum-deposited silver coating. After baking the assembly, the foils were cleaned with an argon glow discharge. The chamber was then installed in a primary proton beam at the Brookhaven AGS. A difference in sensitivity of 6% was noted between the chamber's two emitter foils. After exposure to a flux of 1018 to 1019 protons/cm2, the sensitivity of one of the foils was found to have increased by 0.2% and the other to have decreased by 1.2%. This is substantially better than earlier designs
Original Title
Extracted beam intensity
Primary Subject
Secondary Subject
Source
1979; 2 p; IEEE particle accelerator conference; San Francisco, CA, USA; 12 - 14 Mar 1979; CONF-790327--68; Available from NTIS., PC A02/MF A01