Choi, E.C.; Drolet, T.S.; Stewart, W.B.; Campbell, A.V.
Proceedings of the fifteenth DOE nuclear air cleaning conference1979
Proceedings of the fifteenth DOE nuclear air cleaning conference1979
AbstractAbstract
[en] Ontaro Hydro's radioactive waste incinerator designed to reduce the volume of low-level combustible wastes from nuclear generating station's was declared in-service in September 1977. Hiterto about 1500 m3 of combustible waste have been processed in over 90 separate batches. The process has resulted in 40:1 reduction in the volume and 12.5:1 reduction in the weight of the Type 1 wastes. The ultimate volume reduction factor after storage is 23:1. Airborne emissions has been maintained at the order of 10-3 to 10-5% of the Derived Emission Limits. Incineration of radioactive combustible wastes has been proven feasible, and will remain as one of the most important processes in Ontario Hydro's Radioactive Waste Management Program
Primary Subject
Source
First, M.W. (ed.); Department of Energy, Washington, DC (USA); Harvard Univ., Boston, MA (USA). Harvard Air Cleaning Lab; p. 70-81; Feb 1979; p. 70-81; 15. nuclear air cleaning conference; Boston, MA, USA; Aug 1978
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue