AbstractAbstract
[en] Analysis procedures are described which were used to design a reactor cavity shield system, permitting access to the operating floor in the containment building of a PWR. The design features a stepped upper reactor cavity shield plug with a boron carbide liner and an air gap for cooling the primary concrete shield. Pressure relief is provided by four large 5' x 6' multi-legged downvent tunnels. These tunnels are capped by hinged panels of 4 1/2'' Ricorad and 1 1/4'' steel which are designed to open upon a pressure differential of 1/2 lb/in2
Primary Subject
Source
Lahti, G.P.; Lee, R.R.; Courtney, J.C. (eds.); Oak Ridge National Lab., TN (USA); p. 54-67; Feb 1979; p. 54-67; 1978 winter meeting of American Nuclear Society; Washington, DC, USA; 12 - 16 Nov 1978
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue