[en] The core safety analyses and reactivity control analyses that have been done to support safe operation of the LOFT reactor in the LOCE pre-blowdown (or pre-LOCE) operating mode (Operating Mode 8) for the L2-3 nuclear loss of coolant experiment are presented. Safety analyses done to support LOFT operation in other operating modes (Modes 5, 6, and 7) with changes in operating conditions or assumptions due to requirements for safe operation of the L2-3 test (changes from conditions or assumptions for previous safety analyses for those operating modes) are also presented. The analyses discussed herein do not include analyses for potential loss of coolant accidents, or for accidents during the LOCE blowdown mode (Mode 9), or for potential radiation releases during LOCE operation