Collinson, A.E.; Warneford, I.P.
UKAEA, Springfields. Nuclear Power Development Labs1978
UKAEA, Springfields. Nuclear Power Development Labs1978
AbstractAbstract
[en] The vibrational characteristics of a 7 span straight tube and a 26 span U-tube have been investigated for the effects of fluid medium (air/water), tube-grid clearance, tube-grid contact force, vibration transmission and scale. Measured frequency response and mode shapes compared favourably with theoretical values, vibration with pin-pin tube support being most readily excited. The frequency reduction on immersion in water corresponded to an added mass equivalent to the liquid displaced mass. Dynamic magnifiers varied in the range 12 to 135 with mean values of 30 to 40 in water and 45 to 60 in air. Principal vibration modes and damping values were reproducible in a half-scale model of a U-tube. (author)
Primary Subject
Secondary Subject
Source
Jul 1978; 25 p; British Nuclear Energy Society/UK Atomic Energy Authority conference on vibrations in nuclear plant; Keswick, UK; 9 - 12 May 1978