[en] Described is a computer-based gamma ray spectrometer system using a germanium detector for rapid nondestructive measurement of isotopic and total plutonium concentrations in solutions at nuclear reprocessing plants. Isotopic concentrations have been measured with an accuracy of +-0.5%. Cell design, calibration techniques, and preliminary results are discussed. This system is being installed at the Tokai reprocessing plant in Japan