[en] This work is devoted to the analysis of the performance of a new gamma camera. This camera is characterized by the introduction of an image amplifier between the crystal detector and the localization system which compound four photomultipliers. The appreciation of performances of this new instrument is based on the measure of the physical parameters usually studied in this purpose: energy resolution, spatial resolution, modulation transfert fonction and contrast, sensitivity and deadtime. Furthermore, we have studied the influence of scattered radiation on the value of these parameters. Two studies complete this work: the artificial deterioration of the energy resolution of the camera inserting a noise, to estimate the importance of the energy resolution on the image contrast; the scanning of pulse amplitude spectra obtained from brain of patients in order to evaluate the participation of scattered radiation in the peak's constitution. We present, at last, a quality control programm for scintillation camera
[fr]
Ce travail est consacre a l'etude des performances d'une nouvelle camera a scintillations, caracterisee par l'introduction d'un amplificateur d'image entre le cristal detecteur et le systeme de localisation constitue par quatre photomultiplicateurs. Pour apprecier les performances de cet appareil, nous avons determine les parametres classiques: resolution en energie, resolution spatiale, F. T. M. et contraste, sensibilite et temps mort, et etudie plus particulierement l'influence du rayonnement diffuse sur la valeur de ces parametres. Deux etudes plus originales completent ce travail: la deterioration artificielle de la resolution en energie de la camera par introduction d'un bruit blanc, pour apprecier l'importance de cette resolution sur le contraste de l'image; l'enregistrement de spectres de distribution en energie sur des malades soumis a des scintigraphies cerebrales, pour evaluer la participation du rayonnement diffuse dans la constitution du pic photoelectrique. Nous presentons enfin, un plan de surveillance des cameras a scintillation, facilement applicable dans un service de medecine nucleaireOriginal Title
Etude de l'influence du rayonnement diffuse sur les parametres responsables de la qualite des images en medecine nucleaire
Secondary Subject
Source
1979; 143 p; These (3e Cycle).
Record Type
Report
Literature Type
Thesis/Dissertation
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue