AbstractAbstract
[en] During a Loss of Coolant Experiment (LOCE), the LOFT reactor experiences an acceleration of 10 G's and fuel cladding temperature changes at a rate of 1100 0K/sec. These unparalleled conditions present a unique startup problem to the LOFT program: How can the integrity of the fuel be confirmed so as to minimize operation if damage has occurred. The Level I Requalification Program is designed to accomplish this. It is a progressive series of tests, designed to detect damage at the earliest possible time, and thus preclude or minimize operation if damage exists. First, fuel specialists examine the LOCE data for possible damaging conditions and the results of primary coolant sample analysis for signs of failed fuel. Second, the requalification program proceeds to a series of mechanical and physics tests
Primary Subject
Source
1979; 4 p; American Nuclear Society meeting; San Francisco, CA, USA; 12 - 16 Nov 1979; Available from NTIS., PC A02/MF A01