AbstractAbstract
[en] The experimental data on the working zone in pot vitrification show that the mean wall heat flux (2 W/cm2) is independent of vessel size. A simple model of the heat transfer processes is developed in which natural convection through the glass-forming region is the controlling mechanism. 3 figures
Primary Subject
Source
Chikalla, T.D.; Mendel, J.E. (eds.); Battelle Pacific Northwest Labs., Richland, WA (USA); p. 122-126; May 1979; p. 122-126; International symposium on ceramics in nuclear waste management; Cincinnati, OH, USA; 30 Apr - 2 May 1979