Clement, J.D.; Rust, J.H.; Wan, P.T.; Chow, S.
Georgia Inst. of Tech., Atlanta (USA). School of Nuclear Engineering1979
Georgia Inst. of Tech., Atlanta (USA). School of Nuclear Engineering1979
AbstractAbstract
[en] The preliminary design of a uranium hexafluoride actinide transmutation reactor to convert long-lived actinide wastes to shorter-lived fission product wastes was analyzed. It is shown that externally moderated gas core reactors are ideal radiators. They provide an abundant supply of thermal neutrons and are insensitive to composition changes in the blanket. For the present reactor, an initial load of 6 metric tons of actinides is loaded. This is equivalent to the quantity produced by 300 LWR-years of operation. At the beginning, the core produces 2000 MWt while the blanket generates only 239 MWt. After four years of irradiation, the actinide mass is reduced to 3.9 metric tonnes. During this time, the blanket is becoming more fissile and its power rapidly approaches 1600 MWt. At the end of four years, continuous refueling of actinides is carried out and the actinide mass is held constant. Equilibrium is essentially achieved at the end of eight years. At equilibrium, the core is producing 1400 MWt and the blanket 1600 MWt. At this power level, the actinide destruction rate is equal to the production rate from 32 LWRs
Primary Subject
Secondary Subject
Source
1 Apr 1979; 75 p; Available from NTIS. PC A04/MF A01