Davis, G.E.; Coffield, F.E.
California Univ., Livermore (USA). Lawrence Livermore Lab1979
California Univ., Livermore (USA). Lawrence Livermore Lab1979
AbstractAbstract
[en] The initial goal of the Data Acquisition System (DAS) is to control 11 instruments chosen as the startup diagnostic set and to collect, process, and display the data that these instruments produce. These instruments are described in a paper by Stan Thomas, et. al. entitled ''MFTF Plasma Diagnostics System.'' The DAS must be modular and flexible enough to allow upgrades in the quantity of data taken by an instrument, and also to allow new instruments to be added to the system. This is particularly necessary to support a research project where needs and requirements may change rapidly as a result of experimental findings. Typically, the startup configuration of the diagnostic instruments will contain only a fraction of the planned detectors, and produce approximately one half the data that the expanded version is designed to generate. Expansion of the system will occur in fiscal year 1982
Primary Subject
Source
12 Nov 1979; 4 p; 8. symposium on engineering problems of fusion research; San Francisco, CA, USA; 13 - 16 Nov 1979; CONF-791102--117; Available from NTIS., PC A02/MF A01