AbstractAbstract
[en] Integral activation measurements supported the thermal neutron energy dependence of 238U assumed in the ENDF/B-IV evaluation. The activation measurements were conducted in a thermally insulated graphite block at the side of the SP Reactor. The block was thermally heated to temperatures up to 4500C. In addition to heating, gasolinium filters were used to tailor the neutron spectra incident on the foils. The metallic foils consisted of copper and depleted uranium. Copper served as the 1/v reference. Activation ratios of 238U to 63Cu in the tailored spectrum were compared with corresponding ratios in a well thermalized flux at room temperature. The difference in this ratio is strongly dependent on the energy dependence of the 238U cross section. 8 figures, 1 table
Original Title
25 to 4500C
Primary Subject
Source
1980; 19 p; American Nuclear Society annual meeting; Las Vegas, NV, USA; 8 - 13 Jun 1980; CONF-800607--34; Available from NTIS., PC A02/MF A01
Record Type
Report
Literature Type
Conference; Numerical Data
Report Number
Country of publication
ACTINIDE NUCLEI, BARYON REACTIONS, BARYONS, BETA DECAY RADIOISOTOPES, BETA-MINUS DECAY RADIOISOTOPES, DATA, DATA FORMS, ELECTROMAGNETIC RADIATION, ELEMENTARY PARTICLES, EVEN-ODD NUCLEI, FERMIONS, HADRON REACTIONS, HADRONS, HEAVY NUCLEI, INFORMATION, IONIZING RADIATIONS, ISOTOPES, MINUTES LIVING RADIOISOTOPES, NEUTRONS, NUCLEAR REACTIONS, NUCLEI, NUCLEON REACTIONS, NUCLEONS, NUMERICAL DATA, RADIATIONS, RADIOISOTOPES, TARGETS, URANIUM ISOTOPES
Reference NumberReference Number
INIS VolumeINIS Volume