AbstractAbstract
[en] Results of a wind tunnel study of the wind pressure distribution on a hyperbolic cooling tower 133m high and base diameter of 122m are prese nted. Measurements of wind pressure were made at 16 external and 8 internal levels. The base columns as well as the heat exchangers were reproduced in the model. The heat exchanger caused a small alteration on the overall distribution of the external and internal pressures, with the exception of the region on the wake near the shell bottom where the internal suction was substantially smaller in the model without heat exchanger. (Author)
Original Title
Distribuicao das pressoes devidas ao vento em uma torre de refrigeracao hiperbolica
Primary Subject
Source
Rio Grande do Sul Univ., Porto Alegre (Brazil). Pos-graduacao em Engenharia Civil; 1216 p; 1978; v. 3, p. 1013-1027; Conference on Structural Analysis, Design and Construction in Nuclear Power Plants; Porto Alegre, Brazil; 18 - 20 Apr 1978