Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.013 seconds
AbstractAbstract
[en] The NRC has required PSE and G to demonstrate that Salem Unit 2 has the capability to remove the core decay heat by natural circulation as a direct consequence of the TMI-2 event. Several tests which were delayed were performed at the beginning of September so that the full power operating license would be granted. After a reactor shutdown, the core power drops to about 3% of the full power level due to delayed neutron emission and the resulting decay heat; thus, natural circulation cooling capability of the normal coolant must be proven. The set of tests chosen are characteristic of the failures, whether actual, possible or contrived, associated with TMI - 2 experience
Primary Subject
Source
Agee, L.J. (ed.); Electric Power Research Inst., Palo Alto, CA (USA); p. 16.1-16.17; Apr 1981; p. 16.1-16.17; 1. international RETRAN conference; Seattle, WA, USA; 22 - 24 Sep 1980
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume