Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.014 seconds
AbstractAbstract
[en] Single orifice impactors have been modified to fractionate a full range of aerosol aerodynamic diameters into eight closed and two open ended intervals (> 16, 16-8, 8-4, 4-2, 2-1, 1.0-0.5, 0.50-0.25, 0.12-0.06 and < 0.06 μm). Experimental measurements with a methylene blue aerosol are in reasonable agreement with the theoretical 50% cut-point diameters. Outdoor and industrial-environment samples collected from Tallahassee and Reading, PA, respectively, show wide variations in the mass distributions of 15 elements measured by PIXE and proton elastic scattering analyses (PESA). The ten intervals provide adequate resolution to characterize the aerosol in a region of great environmental interest. (orig.)
Primary Subject
Secondary Subject
Source
2. International conference on particle induced X-ray emission and its analytical applications (PIXE-2); Lund, Sweden; 9 - 12 Jun 1980
Record Type
Journal Article
Literature Type
Conference
Journal
Nuclear Instruments and Methods; ISSN 0029-554X;
; v. 181(1-3); p. 499-502

Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue