[en] After some tests in a PS beam in the summer of 1981, the run took place in October 1981 in the H2 beam of the SPS. Although some problems of heat dissipation in freon limited the expansion rate of the bubble chamber, more than 11000 holograms were taken, showing 10 μm bubble tracks, with very good image quality and contrast. More than 100 tracks can be stored on a hologram without affecting the quality if all the bubbles are small. In addition, the analysis of the holograms does not look more complex than the exploitation of conventional high-resolution pictures. (orig./HSI)
Source
European Organization for Nuclear Research, Geneva (Switzerland); 252 p; 22 Mar 1982; p. 56-61; European Hybrid Spectrometer workshop on holography and high-resolution techniques; Strasbourg, France; 9 - 12 Nov 1981