Denisov, V.F.; Ivanov, D.P.; Kislov, A.Ya.; Kochin, V.A.; Maksimov, Yu.S.; Stavisskij, B.A.; Khvostenko, P.P.; Khilil', V.V.; Chumakov, G.D.
Gosudarstvennyj Komitet po Ispol'zovaniyu Atomnoj Ehnergii SSSR, Moscow. Inst. Atomnoj Ehnergii1981
Gosudarstvennyj Komitet po Ispol'zovaniyu Atomnoj Ehnergii SSSR, Moscow. Inst. Atomnoj Ehnergii1981
AbstractAbstract
[en] Stable discharges in the tokamak with a superconducting winding of a longitudinal magnetic field are obttained and investigated. Stable discharge currents constitute Isub(p)=150-180 kA at by- pass voltage U=1.6-2.8 B and q=2.6-3.1. It is shown, that the superconducting winding is insensitive to variable magnetic field perturbations. A complete applicability of the device with the superconducting toroidal magnetic field system is shown for conducting regular plasma experiments. The interval between discharge pulses reached 3 min at discharge current up to 240 kA. An obvious achievement of the present experiment series is to be considered a continuous operation of the device and its cryogenic complex during two months, f or this period impurity freezing in a refrigerator occuring several times. It turned to be possible however to stop coolant supply to the superconducting magnetic system, heat the refrigerator, blow it through and to return to the working mode for 3-4 h
[ru]
Original Title
Rezul'taty pervykh ehksperimentov s plazmoj na ustanovke Tokamak-7 so sverkhprovodyashchej obmotkoj
Primary Subject
Source
1981; 8 p; 3 refs.; 3 figs.
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue