AbstractAbstract
[en] An elaborate study was carried out for the coil and biological shield of the ELMO Bumpy Torus proof-of-principle (EBT-P) device. A three-dimensional scoping study for the coil shield was performed for four different shielding options to define the heat load for each component and check the compliance with the design criterion of 10 watts maximum heat per coil from the gamma ray sources. Also, a detailed biological dose survey was performed which included: (a) the dose equivalent inside and outside the building, (b) the dose equivalent from the two mazes of the machine room, and (c) the skyshine contribution to the dose equivalent
Primary Subject
Source
Dec 1981; 81 p; Available from NTIS., PC A05/MF A01 as DE82017658
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue