Legrele, C.; Lugol, J.C.
CEA Centre d'Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)1982
CEA Centre d'Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)1982
AbstractAbstract
[en] A one-nanosecond resolution time-to-digital converter for the SPES I detection near Saturne II has been built. Full ranges are 1 μs or 8 μs. A 125 MHz gated oscillator triggered by the start gives after a four-phase demultiplier a set of 16 signals of 32 ns period delayed by 1 ns. The stop memorizes 32 different configurations for the fine count in Gray code. The differential non linearity is = 0.25 ns
Source
Oct 1982; 4 p; IEEE nuclear science symposium; Washington, DC (USA); 20 - 22 Oct 1982