Brown, B.C.; Cooper, W.E.; Garvey, J.D.
Fermi National Accelerator Lab., Batavia, IL (USA)1983
Fermi National Accelerator Lab., Batavia, IL (USA)1983
AbstractAbstract
[en] The measurement system and procedures used to test more than 900 superconducting dipole magnets and more than 275 superconducting quadrupole magnets for the Fermilab Energy Saver are described. The system is designed to measure nearly all parameters relevant to the use of the magnets in the accelerator including maximum field capability and precision field measurements. The performance of the instrumentation with regard to precision, reliability, and operational needs for high volume testing will be described. Previous reports have described the measurement system used during development of the Saver magnets from which this system has evolved