AbstractAbstract
[en] Exposure rates from cylindrical waste units containing the nuclides 60Co, 134Cs and 137Cs homogeneously mixed in a solidification product have been calculated. Analyses have been made for single drums and for two disposal geometries, one with the units placed below ground near the surface in a circular geometry, and one with the units placed on the ground in a pile behind a concrete wall. Due to self-shielding of the units, the exposure rate from the two geometries will be a factor of only 10 - 20 higher than from a single unit, even without soil or wall shielding. With one meter of soil above the circular pile below ground, a reduction factor of 5.103 to 5.104 can be achieved, depending on the nuclide considered. Placing a one-meter concrete wall in front of the drum pile on the ground gives rise to a reduction factor in the range of 5.105 to 2.107. (author)
Primary Subject
Source
Mar 1983; 36 p; ISBN 87-550-0932-8;
; Also available from Risoe Library, DK-4000 Roskilde, Denmark