Li, T.K.; Sampson, T.E.; Johnson, S.S.
Los Alamos National Lab., NM (USA)1983
Los Alamos National Lab., NM (USA)1983
AbstractAbstract
[en] An automated at-line plutonium isotopic analysis system for small-product plutonium samples in the range of 10 to 1000 μg has been developed. The analysis is based on low-energy gamma rays at 43.48 keV (238Pu), 45.23 keV (240Pu), 51.63 keV (239Pu), 64.83 keV (241Pu-237U), 129.3 keV (239Pu), and 148.6 keV (241Pu). Within a 20-ks counting time, we demonstrated that for plutonium masses > 600 μg the precision is < 0.7% for 238Pu/239Pu and 240Pu/239Pu ratios and approx. 4% for the 241Pu/239Pu ratio. The agreement between the results measured by gamma-ray spectroscopy and those measured by mass spectrometry for seven samples is within the gamma-ray precision limits
Primary Subject
Secondary Subject
Source
1983; 4 p; 5. symposium on safeguards and nuclear material management; Versailles (France); 19-21 Apr 1983; CONF-830423--10; Available from NTIS, PC A02/MF A01 as DE83011172
Record Type
Report
Literature Type
Conference; Numerical Data
Report Number
Country of publication
ACTINIDE NUCLEI, ALPHA DECAY RADIOISOTOPES, BETA DECAY RADIOISOTOPES, BETA-MINUS DECAY RADIOISOTOPES, CHEMICAL ANALYSIS, DATA, EVEN-EVEN NUCLEI, EVEN-ODD NUCLEI, HEAVY NUCLEI, INFORMATION, ISOTOPES, NUCLEI, NUMERICAL DATA, ON-LINE SYSTEMS, QUANTITATIVE CHEMICAL ANALYSIS, RADIOISOTOPES, SPECTROSCOPY, YEARS LIVING RADIOISOTOPES