Massey, R.S.; Buchenauer, C.J.; Burkhardt, L.C.; Jacobson, A.R.; Melton, J.G.; Miller, G.; Moses, R.W.; Schoenberg, K.F.; Watt, R.G.
Los Alamos National Lab., NM (USA)1983
Los Alamos National Lab., NM (USA)1983
AbstractAbstract
[en] Studies have been made of the effects of equilibrium control and field-error reduction in ZT-40M. Certain plasma parameters, most notably the termination time, were found to be affected by equilibrium positioning and field errors. Modifications to the machine to improve the equilibrium and reduce field errors have significantly improved the machine performance
Primary Subject
Source
Feb 1983; 28 p; Available from NTIS, PC A03/MF A01 as DE83010139