[en] Engineering problems encountered in the development of nuclear borehole logging techniques are discussed. Spectrometric techniques require electronic stability of the equipment. In addition the electronics must be capable of handling high count rates of randomly distributed pulses of fast rise time from the detector and the systems must be designed so that precise calibration is possible under field operating conditions. Components of a logging system are discussed in detail. They include the logging probe (electronics, detector, high voltage supply, preamplifier), electronic instrumentation for data collection and processing and auxiliary equipment
Primary Subject
Source
Watt, J.S.; Sowerby, B.D. (eds.); Australian Atomic Energy Commission Research Establishment, Lucas Heights; 471 p; Oct 1982; p. 383-399