AbstractAbstract
[en] The safety of pressure circuit components is discussed with respect to coolant loop piping, coolant pumps, pressuriser, steam generator channel head and shell, primary component supports and restraints, accumulators, main steam line no-break zone, reactor internals and core, and valves including main steam isolating valves. Outstanding issues are identified and a programme of additional work is discussed. (U.K.)
Primary Subject
Source
Jul 1983; 14 p; ISBN 07176 0158 7;