Ahme, J.; Bieler, C.; Marks, J.; Riebesell, M.; Spitzer, H.; Wittenburg, K.; Winter, G.G.
Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany, F.R.)1983
Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany, F.R.)1983
AbstractAbstract
[en] We have used silicon photodiodes in combination with a wavelength shifter to read out lead-scintillator shower counters in tests with incident electrons of 0.5 to 5.5 GeV. An r.m.s. noise equivalent of 108 MeV for an effective radiation length of 2.24 cm and of 183 MeV for Xsub(eff) = 1.4 cm has been observed. For a samplig of 2 mm lead and 6 mm scintillator a resolution of sigma/E = 0.12/√E is reached between E = 2 and 5.5 GeV. (orig.)
Source
Oct 1983; 11 p; With 10 refs., 1 tab., 4 figs. Submitted to Nucl. Instr. Math.