Hibbs, S.M.; Kane, R.J.; Kerr, R.G.; Poulsen, P.
Lawrence Livermore National Lab., CA (USA)1983
Lawrence Livermore National Lab., CA (USA)1983
AbstractAbstract
[en] During construction of the Tandem Mirror Experiment-Upgrade (TMX-U), we assembled a test stand to develop electronics for the neutral beam system. In the first six months of test stand use we operated a few neutral beam injector modules and directed considerable effort toward improving the electronic system. As system development progressed, our focus turned toward improving the injector modules themselves. The test stand has proved to be the largest single contributor to the successful operation of neutral beams on TMX-U, primarily because it provides quality assurance andd development capability in conjunction with the scheduled activities of the main experiment. This support falls into five major categories: (1) electronics development, (2) operator training, (3) injector module testing and characterization, (4) injector module improvements, and (5) physics improvements (through areas affected by injector operation). Normal day-to-day operation of the test stand comes under the third category, testing and characterization, and comprises our final quality assurance activity for newly assembled or repaired modules before they are installed on TMX-U
Primary Subject
Source
2 Dec 1983; 6 p; 10. symposium on fusion engineering; Philadelphia, PA (USA); 5-9 Dec 1983; CONF-831203--102; Available from NTIS, PC A02/MF A01 as DE84006302
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue