Lo, T.; Woo, H.H.; Holman, G.S.; Chou, C.K.
Lawrence Livermore National Lab., CA (USA)1984
Lawrence Livermore National Lab., CA (USA)1984
AbstractAbstract
[en] This paper describes the results of assessments performed on the PWR coolant loop piping of Westinghouse and Combustion Engineering plants. For direct double-ended guillotine break (DEGB), consideration was given to crack existence probability, initial crack size distribution, hydrostatic proof test, preservice inspection, leak detection probability, crack growth characteristics, and failure criteria based on the net section stress failure and tearing modulus stability concept. For indirect DEGB, fragilities of major component supports were estimated. The system level fragility was then calculated based on the Boolean expression involving these fragilities. Indirect DEGB due to seismic effects was calculated by convolving the system level fragility and the seismic hazard curve. The results indicate that the probability of occurrence of both direct and indirect DEGB is extremely small, thus, postulation of DEGB in design should be eliminated and replaced by more realistic criteria
Original Title
Double-ended guillotine break
Primary Subject
Source
Feb 1984; 17 p; Available from NTIS, PC A02/MF A01 as DE84009540
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue