[en] A substantial quantity of high beta-gamma/high-TRU contaminated wastes are expected from cleanup activities of Unit 2 of the Three Mile Island Nuclear Power Station. Those wastes are not disposable because of present regulatory constraints. Therefore, they must be stored temporarily. This paper discusses three options for storage of those wastes at the Idaho National Engineering Laboratory: (1) storage in temporary storage casks; (2) underground storage in vaults; and (3) storage in silos at a hot shop. Each option is analyzed and evaluated. Also included is a discussion of future disposal strategies, which might be pursued when a suitable federal or commercial repository is built
Primary Subject
Secondary Subject
Source
Mar 1984; 6 p; Waste management '84; Tucson, AZ (USA); 11-15 Mar 1984; CONF-840307--40; Available from NTIS, PC A02/MF A01; 1 as DE84011746