Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.016 seconds
McIsaac, C.V.; Davis, C.M.; Horan, J.T.; Keefer, D.G.
EG and G Idaho, Inc., Idaho Falls (USA)1984
EG and G Idaho, Inc., Idaho Falls (USA)1984
AbstractAbstract
[en] The Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI-2 Reactor Building during February and March 1982 and was designed to investigate the effectiveness of various surface decontamination techniques. The polar crane, D-rings, missile shields, refueling canal, fueling bridge, major equipment, floors and some walls were flushed with low pressure water. Water lances were directed manually and applied water at temperatures between ambient and 600C at a flow rate of about 95 liters per minute. In addition, floor surfaces on the 305-ft elevation and floor surfaces and major equipment on the 347-ft elevation were sprayed with high pressure water (floors in the Reactor Building are designated by their elevations above sea level). The water pressure in this case varied between 13.8 and 41.4 mPa and water temperature was at a maximum 600C. Certain surfaces were also decontaminated using either strippable coatings or a mechanical scrubbing device
Primary Subject
Source
1984; 16 p; Topical meeting on fission product behavior and source term research; Snowbird, UT (USA); 15-19 Jul 1984; CONF-840701--24; Available from NTIS, PC A02/MF A01; 1 as DE84016217
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue