[en] The available corrosion literature was reviewed in order to estimate the extent of corrosion that would occur to electrically isolated Type 316L stainless steel buried at a depth of 14 m at the Hanford commercial low-level radioactive waste disposal site. After 300 y of exposure in Burbank loamy sand the estimated corrosion is as follows: the average uniform metal loss would be less than 1 mil; pitting penetration is estimated at 200 mil; and the pit density (assuming that all of the metal loss is due to pitting and that all of the pits are of uniform depth) should be less than 1 pit/ft2. 7 figures, 9 tables
Primary Subject
Secondary Subject
Source
Nov 1984; 39 p; Available from NTIS, PC A03/MF01; 1 as DE85006376
Record Type
Report
Report Number
Country of publication
ALLOYS, AUSTENITIC STEELS, CARBON ADDITIONS, CHEMICAL REACTIONS, CHROMIUM ALLOYS, CHROMIUM-NICKEL STEELS, CORROSION RESISTANT ALLOYS, HEAT RESISTING ALLOYS, HIGH ALLOY STEELS, IRON ALLOYS, IRON BASE ALLOYS, LOW CARBON-HIGH ALLOY STEELS, MATERIALS, MOLYBDENUM ALLOYS, NICKEL ALLOYS, RADIOACTIVE MATERIALS, RADIOACTIVE WASTES, STAINLESS STEELS, STEELS, WASTES