[en] A fast neutron transmission system for canister glass level detection in the Defense Waste Processing Facility has been developed and evaluated. The system is capable of glass level detection within 3/16 inch and of detecting an abnormal (coning) fill condition
Primary Subject
Source
1984; 22 p; Joint meeting of the American Nuclear Society and the Atomic Industrial Forum; Washington, DC (USA); 11-16 Nov 1984; CONF-841105--64; Available from NTIS, PC A02/MF A01; 1 as DE85007909