Faibis, A.; Koenig, W.; Kanter, E.P.; Vager, Z.
Argonne National Lab., IL (USA)1985
Argonne National Lab., IL (USA)1985
AbstractAbstract
[en] It has long been recognized that the foil-induced dissociation of fast molecular ions is a potentially powerful method to determine the stereochemical structures of the molecular projectiles. We have recently developed a detector system specifically designed for such experiments. The MUPPATS detector is a large-area multistep low pressure gas counter. The requirements of multiparticle detection with good position and time resolution leads to a rather complex data-readout and reduction scheme. The system relies on several state-of-the-art techniques, developed in high-energy physics during recent years, to dramatically reduce the cost of the MUPPATS detector. Preliminary results for several polyatomic molecular ions have already been obtained. Some new avenues of research opened up by this detector are also described
Primary Subject
Source
27 Aug 1985; 18 p; 11. international conference on atomic collisions in solids; Washington, DC (USA); 4-9 Aug 1985; Available from NTIS, PC A02/MF A01; 1 as DE85018451
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue