AbstractAbstract
[en] Two single-cavity prestressed concrete reactor vessel (PCRV) models were fabricated and tested to failure to demonstrate the structural response and ultimate pressure capacity of models cast from high-strength concretes. Concretes with design compressive strengths in excess of 70 MPa (10,000 psi) were developed for this investigation. One model was cast from plain concrete and failed in shear at the head region. The second model was cast from fiber reinforced concrete and failed by rupturing the circumferential prestressing at the sidewall of the structure. The tests also demonstrated the capabilities of the liner system to maintain a leak-tight pressure boundary. 3 refs., 4 figs
Primary Subject
Secondary Subject
Source
1985; 9 p; 8. international conference on structural mechanics in reactor technology; Brussels (Belgium); 19-23 Aug 1985; Available from NTIS, PC A02/MF A01 as DE85016311