Apsimon, R.J.; Flower, P.S.; Freeston, K.A.
Stanford Linear Accelerator Center, Menlo Park, CA (USA); Rutherford Appleton Lab., Chilton (UK); European Organization for Nuclear Research, Geneva (Switzerland); Manchester Univ. (UK). Schuster Lab.; Sheffield Univ. (UK)1985
Stanford Linear Accelerator Center, Menlo Park, CA (USA); Rutherford Appleton Lab., Chilton (UK); European Organization for Nuclear Research, Geneva (Switzerland); Manchester Univ. (UK). Schuster Lab.; Sheffield Univ. (UK)1985
AbstractAbstract
[en] We discuss the design and construction of the Time Projection chambers (TPCs) of the Omega Ring Imaging Cerenkov Detector (RICH). Details are given of the TPC high voltage system and its monitoring and control. In addition, the operation and monitoring of the readout is described together with results of tests on the performance of the front end amplifiers. The operation of the RICH TPCs and electronics during the first data run of WA69, in 1984, is discussed together with relevant results from laboratory tests. Results from the preliminary analysis of a sample of data from the 1984 run are also presented
Source
Oct 1985; 10 p; IEEE nuclear science symposium; San Francisco, CA (USA); 23-25 Oct 1985; CONF-851009--6; Available from NTIS, PC A02/MF A01; 1 as DE86002810
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume