[en] This paper presents graphs of comparison experiment - calculation (code RELAP4-MOD6) for the three following points in the case of a LOCA on the primary circuit: depressurization, first rise of temperature and stagnation point; bypass refilling
[fr]
Cet article presente un ensemble de courbes de comparaison experience-calcul (code RELAP4-MOD6) en ce qui concerne les 3 points suivants lors d'un accident de perte de refrigerant sur le circuit primaire: depressurisation, premier pic de temperature paroi crayon chauffant et point de stagnation, bypass remplissageOriginal Title