[en] Estimates of the spatial resolution of a liquid argon ionization drift chamber are presented in the paper. The results obtained exhibit a possibility to construct a simple coordinate detector with a spatial resolution of σx = 20 μm and a two-track separation better than 1 mm, while good energy resolution characteristics for the LA detector are being conserved. The calculations were performed for an ionization cylindrical chamber with the cathode and anode diameter 4 cm and 0.1 mm, respectively. The fluctuations of ionization losses in thin samples and the noise jitter after shaping were taken into account in the analysis. (orig.)
Record Type
Journal Article
Journal
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment; ISSN 0168-9002;
; CODEN NIMAE; v. 254(1); p. 44-53