AbstractAbstract
[en] Calculation technique for heat exchangers with saturated and underheated He-2 under conditions of natural inner convection and forced convection is delivered. The following variants of heat exchangers are considered: inside the bath with saturated He-2 a tube is placed along which subcooled He-2 flow moves with a constant rate; inside the bath with subcooled He-2 a tube is placed both ends of which are in the bath with saturated He-2; inside the bath with saturated He-2 a tube is placed both ends of which are in the bath with subcooled He-2. For all cases examples of calculation and experimental data of heat exchanger tests are presented. The developed methods of calculation of heat exchangers for saturated He-2 and subcooled He-2 make it possible to design and create superfluid helium cryostatting systems
Original Title
Raschet teploobmennykh apparatov s nasyshchennym i nedogretym sverkhtekuchim geliem (He-2)
Record Type
Journal Article
Literature Type
Numerical Data
Journal
Izvestiya Akademii Nauk SSSR, Ehnergetika i Transport; ISSN 0002-3310;
; CODEN IAETA; (no.3); p. 133-141

Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue